Software service functions
Service utilities
The control panel SERVICE menu provides utilities for technicians rigging or servicing the fixture:
ERROR LIST displays any error messages that are stored in internal memory.
PT FEEDBACK lets you disable feedback to the fixture software from the pan, tilt and effects positioning
systems. If feedback is set to ON and a pan, tilt or effect position error is detected, the shutter closes and
the effect resets. This feature can be disabled by setting feedback to OFF.
The OFF setting is not saved when the fixture is powered off, and the system will be re-enabled the next
time the fixture starts. If a pan/tilt position error occurs and the system cannot correct pan/tilt position
within 10 seconds, feedback is automatically disabled.
ADJUST is for use at the factory and by authorized Martin Service technicians only. This menu allows
dimmer and frost positions to be adjusted after replacement of components, etc. To adjust the default
positions of all the MAC Viper Profile’s effects, use the CALIBRATION menu instead.
Important! Do not enter the ADJUST menu without service documentation from Martin.
CALIBRATION lets you set new default positions for calibration purposes, set effects to their factory
default positions or overwrite the factory default positions with new values. See ”Calibration” below.
USB lets you updates the firmware (fixture software) using a USB memory device. For a detailed guide to
updating the firmware, see ”Installing using a USB memory device” later in this chapter.
Calibration
The CALIBRATION menu lets you define offsets in software that are relative to the mechanical reset or
home positions. This allows you to fine-tune optical alignment and achieve uniform performance between
fixtures. Fixtures are adjusted and calibrated at the factory, and further calibration will normally only be
necessary if fixtures have been subjected to abnormal shocks during transport or if normal wear and tear
has affected alignment after an extended period of use.
Calibrating pan and tilt sensors
Warning! Be ready for the head to move during pan and tilt calibration.
To calibrate pan and tilt:
1. Place the fixture on a stable surface.
2. In the CALIBRATION menu, select PT AT END STOP.
3. Move pan to its end stop position by rotating the yoke clockwise (as seen from above the head looking
towards the base) to maximum pan.
4. Move tilt to its end stop by tilting the head to its maximum angle with the front glass pointing towards the
base and away from the display/control panel.
5. Be ready for the head to move. Click the jog wheel to register the positions. The fixture will display
Saving... and the head will move.
6. Press the Escape button to exit pan/tilt sensor calibration. Be ready for the head to move again.
Calibrating effects
Calibration can be carried out via DMX (see ”Changing calibration offsets using DMX” on page 17) but the
most thorough approach is probably to set multiple fixtures to the same position (e.g. dimmer open 1%) and
then calibrate each fixture using its onboard control panel while comparing its light output with a reference
fixture.The calibration range available for each effect varies but is approximately 5%. After selecting a
calibration value, click on the jog wheel to set the effect to that value.