8 Operation
STATUS
The three LEDs on the rear panel of the smoke machine indicate the machines
status.
POWER (red):
There is power to the heater.
HEAT (red)
: The machine is heating. The LED flashes rapidly and then more
slowly as the heating cycle nears the end. It turns off when the heating element has
reached maximum temperature. The heating cycle for a cold machine takes 8 to 10
minutes.
READY (green)
: Ready to produce smoke. The HEAT and READY LEDs can be
on simultaneously as smoke production is possible when the machine is heating.
MANUAL OPERATION
As soon as the green READY LED turns on, you can make smoke by pressing the
Smoke button on the control unit. The output level can be adjusted using the Smoke
output knob.
Though the fluid pump stops when you release the Smoke button, smoke emission
will continue for another few seconds because the fluid in the heating element is
under pressure.
AUTO-TIMER
The auto-timer allows you to program output duration and level at repeatable
intervals. The maximum programmable interval (output duration + pause) is
approximately 1 hour.
The auto-timer sequence is stored in the smoke machine’s memory and is not
cleared when disconnecting the machine from mains power. When switched on, the
machine will execute the auto-timer sequence as soon the machine is ready.
Adjusting the smoke output potentiometer does not override the stored auto-timer
level. You can still produce smoke manually and, if this level is higher than the
stored level, it will take precedence.
To set the auto-timer
1 Adjust the Smoke output knob to the desired level.
2 Press the smoke button for the desired output duration.
3 Wait for the desired pause time and then press the timer store button.
Page view 7