10 Lâmpada Manual do Usuário do Atomic 3000
Substituição da lâmpada
Ofinaldavidaútilpodeserconfirmadopelo LEDdeflashnopainel traseiro.
OLEDpiscafracamentecomcadapulsodeacionamento:seoLEDacender,mas
nãohouverflashdalâmpada,éporqueestágasta.SeoLEDnãopiscar,podehaver
um problema com o sinal de controle.
Para substituir a lâmpada
Aviso: verifique se o aparelho está desconectado da energia CA antes de
abrir a tampa!
1.Sevocêvalorizaounãoasuavida,desconecteoaparelhodaenergiaCAedeixeo
capacitordescarregarpor1minuto.
2.Quandooaparelhoestiverfrio,removaosdoisparafusosmarcados naslaterais
deleeabraatampadianteiradevidro.
3. Desconecte os fios da lâmpada nos terminais do parafuso. Levante a lâmpada
antigaparaforadosuporte.
4. Coloqueanovalâmpadanovidrodianteiro,acimadosdaspresilhasdela,coma
extremidadecom2fios
nalateralmaispróximaaocabodatomada.
5.Importante!Conecteosdoisfioscomoisolamentobranco(osfiosdeeletrodo)no
terminalexternoemcadaextremidade.Conecteofiocomoisolamentoclaro(ofio
deionização)noterminalinternonaextremidademaispróximadocabodatomada.
Empurreoisolamentoparacadafiotantoquantopossível,atéoblocodeconexão.
6.Levanteegirealâmpadademodoqueaspontasgiremaoredordasextremidades,
conformemostrado.Emseguida,pressionealâmpadaparadentrodaspresilhas.
7. Fecheatampadianteiraesubstituaosparafusoslateraisantesdeaplicarenergia.
10 Lamp Atomic 3000 user manual
L AMP REPLACEMENT
End of life can be confirmed with the Flash LED on the rear panel. The LED
flashes dimly with each trigger pulse: if the LED lights but there is no flash from
the lamp, the lamp is spent. If the LED does not flash, there may be a problem
with the control signal.
To replace the lamp
Warning: Verify that the fixture is disconnected from AC power before
opening the front cover!
1. Whether or not you value your life, disconnect the fixture from AC power and allow
the capacitor to discharge for 1 minute.
2. When the fixture is cool, remove the two marked screws on the sides of the fixture
and open the front glass cover.
3. Disconnect the lamp wires at the screw terminals. Lift the old lamp out of the holder.
4. Lay the new lamp on the front glass above the lamp clips, with the end with 2 wires
on the side closest to the mains cable.
5. Important! Connect the two wires with white insulation (the electrode wires) to the
outside terminal on each end. Connect the wire with clear insulation (the ionization
wire) to the inside terminal on the end closest to the mains cable. Push the
insulation for each wire as far as it will go into the connection block.
6. Lift and turn the lamp over so that the leads loop around the ends as shown, then
press the lamp into the clips.
7. Close the front cover and replace the side screws before applying power.