Martin M2GO and M2PC Safety and Installation Guide
Power Connections
Martin M2GO - M2PC accepts AC mains power at 100-240V 50/60Hz. Do not connect it to
power outside this range. Damage resulting from incorrect connection is not covered under warranty.
North America: A cable with a NEMA 15-5P plug is provided for use with the M2GO - M2PC in the
USA and Canada. This approved cable must be used in North America.
Rest of the world: The provided IEC cable is not fitted with a country-specific plug.
Install only a plug that meets local and national electrical codes and is suitable for the country's
specific power outlet types. Refer to a certified electrician for any questions regarding a country's
specific requirements.
A 3-prong grounding-type (earthed type) plug must be installed following the plug manufacturers
instructions. The table below shows some possible pin identification schemes; if the pins are not
clearly identified, or if you have any doubts about proper installation, consult a qualified electrician.
Wire color (standard EU code)
Pin
Symbol
brown
live
L
blue
neutral
N
yellow/green
ground
1. Check the power switch and ensure that it is set to the center OFF position.
2. Insert the XLR 4-pin connector from the power supply unit into the power input on the back of the
desk
3. Insert the provided power cable into the IEC connector of the power supply unit and connect the
cable to a properly protected and grounded power outlet.
4. M2GO: Connect an external touch-enabled monitor, e.g. ELO 2201L with both the video and USB
connections.
M2PC: Connect the USB cable to the PC system
5. Turn on the desk by toggling the power switch to the CPU position (M2GO) or USB position
(M2PC)