Martin SynchroZap QX250 User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
23
T
ROUBLESHOOTING
Problem Probable cause(s) Remedy
LEDs fail to light.
No power. Check that power is
switched on and cables
are plugged in.
Internal circuit
breaker open.
Disconnect the
controller for several
minutes to reset the
circuit breaker. Consult
service technician if
problem reoccurs.
Fixtures fail to
respond to controller.
Bad data connection. Inspect data cables and
connections, repair or
replace damaged
cables.
The data link is not
connected.
Connect data link.
Missing termination. Insert termination plug
in output of last fixture.
Incorrect address or
mode setting.
Check and correct DIP-
switch settings.
Lights not powered
on.
Power on lights.
Lights have failed in
the protocol auto-
detection.
Switch off the lights
and then back on again.
In general, switch on
the MC-Showtime
controller before the
lights.
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26

Comments to this Manuals

No comments