Martin DMX 5.3 Splitter User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
8 MAC Aura user manual
AC power
Warning! Read “Safety Information” starting on page 3 before connecting the MAC Aura to AC
mains power.
Warning! For protection from electric shock, the MAC Aura must be grounded (earthed). The power
distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault)
protection.
Warning! Socket outlets or external power switches used to supply the MAC Aura with power must
be located near the fixture and easily accessible so that the fixtures can easily be disconnected
from power.
Important! Do not insert or remove live Neutrik PowerCon connectors to apply or cut power, as this
may cause arcing at the terminals and damage the connectors.
Important! Do not use an external dimming system to supply power to the MAC Aura, as this may
cause damage to the fixture that is not covered by the product warranty.
Power voltage
Warning! Check that the voltage range specified on the fixture’s serial number label
matches the local AC mains power voltage before applying power to the fixture.
MAC Aura fixtures accept AC mains power at 100-240 V nominal, 50/60 Hz. Do not apply AC mains power
to the fixture at any other voltage than that specified on the fixture’s serial number label.
Power cables and power plug
The MAC Aura requires a power input cable with a Neutrik PowerCon NAC3FCA cable connector for AC
mains power input. The cable must meet the requirements listed under “Protection from electric shock” on
page 3.
Martin™ can supply either a suitable 3 m (9.8 ft.) power cable with PowerCon input connector installed or
the PowerCon input connector without a cable (see “Accessories” on page 34).
The MAC Aura can be hard-wired to a building electrical installation if you want to install it permanently, or a
power plug that is suitable for the local power outlets can be installed on the power cable.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A
minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes
and some possible pin identification schemes; if pins are not clearly identified, or if you have any doubts
about proper installation, consult a qualified electrician.
Wire Color
(EU models)
Wire Color
(US models)
Conductor Symbol Screw (US)
brown black live L yellow or brass
blue white neutral N silver
yellow/green green ground (earth) or green
Table 1: Wire color-coding and power connections
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 35 36

Comments to this Manuals

No comments