Martin MAC 401 Dual User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
Onboard control menus 31
INFO
VERS
MAIN
CPU firmware version in main processor
HEAD
CPU firmware version in head processor front module / rear module (if
installed)
pOHR
RSET
Hours of operation since counter reset (to reset counter, display counter
and press [Up] for 5 secs.)
TOTL
Total hours of operation since manufacture
MTMP
CURR
Display current main PCB temperature
MSR
Display highest main PCB temperature since last reset
MR
Display highest main PCB temperature since manufacture
DTMP
CURR
Display current average driver PCB temperature
MSR
Display highest driver PCB temperature since last reset
MR
Display highest driver PCB temperature since manufacture
PTMP
CURR
Display current average pixel PCB temperature
MSR
Display highest pixel PCB temperature since last reset
MR
Display highest pixel PCB temperature since manufacture
AIRF
TOTL
Current elapsed time in hours since the air filter was cleaned or
changed. Display the counter and press the up button for five seconds
to reset it.This counter must be reset manually when the air filter is
cleaned.
STTM
Set duration of time alert to be issued after 100-9999 hours have
passed on the
TOTL counter, to remind you to clean it, particularly the
air filter. The alert appears as long as the value of the
TOTL counter
is higher than the threshold set here.
SNUM
RDM
Display fixture’s RDM ID
SNUM
Display fixture’s serial number
MAN
RST
Reset fixture. Press [Enter] to confirm
ALL 0 255
All LEDs, intensity 0 - 100%
RED 0 255
Red LEDs, intensity 0 - 100%
GRN1 0 255
Green 1, intensity 0 - 100%
GRN2 0 255
Green 2, intensity 0 - 100%
BLUE 0 255
Blue, intensity 0 - 100%
ZOOM 0 255
Zoom full wide zoom full narrow (Hypermode)
TILT 0 255
Full tilt full opposite tilt
PAN 0 255
Pan full left pan full right
TEST
TALL
Test LEDs, zoom and pan/tilt movement
T-FX
Test LEDs and zoom only
TP-T
Test pan/tilt movement only
TDIS
Light all segments in onboard display panel for 5 secs.
DMXL
RATE
DMX transmission speed, live, in packets per second
QUAL
Percent of packets received with errors, live
STRT
Decimal value of the DMX start code, live
SERV
To access
this menu,
hold
[Enter]
pressed for
a few
seconds
PTFB
ON
Enable pan/tilt position feedback/correction system
OFF
Disable pan/tilt feedback (this setting is not saved when fixture is reset)
ADJ
Effects adjustment menu (for service use: for full details of this menu,
see “Adjustment submenu” on page 35)
CAL
(OF = offset)
P OF
Pan calibration
T OF
Tilt calibration
DOF SURE
Load factory effects calibration settings
PCBT SURE
PCB test: for service use only
UPLD SURE
Manually set fixture to receive software upload
HEAD
DUAL
Sets head to dual head module operation
SNGL
Sets head to single head module operation
Menu Item Options Notes (Default settings in bold print)
Table 4: Control menu: single head module operation
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 39 40

Comments to this Manuals