10 MAC 2000 Wash
AC
POWER
WARNING! For protection from electric shock, the fixture must be grounded (earthed). The AC mains
supply shall be fitted with a fuse or circuit breaker and ground-fault protection.
Power supply
The MAC 2000 Wash comes with an auto-sensing, auto-ranging switch-mode power supply. Manual adjustments are
not necessary as the MAC 2000 Wash automatically adapts to the mains voltage and frequency.
Fuses
The MAC 2000 Wash comes with two:
20 AT (time delay) main fuses for use with AC supplies of 100 - 120 volts.
15 A main fuses for use with AC supplies of 200 - 250 volts.
Install the appropriate fuses in the holders near the power switch.
Power connection
Important! Connect the MAC 2000 Wash directly to AC power. Do not connect it to a dimmer system;
doing so may damage the fixture.
You may need to install a cord cap that fits your supply on the power cable. A 3-prong grounding-type plug must be
installed following the manufacturer’s instructions. The table shows some possible pin identification schemes; if the
pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician.
To apply power, set the power switch on the base to the “I” position.
Reduced power function
The MAC 2000 Wash has an automatic power reduction function, which reduces the consumption to 700W if the
shutter/dimmer is closed for more than 10 seconds. This not only increases the lamp life, but also further decreases the
overall noise emission of the fixture.
Wire Color Pin Symbol Screw (US)
brown live L yellow or brass
blue neutral N silver
yellow/green ground green
Table 1: Cord cap connections