22 MAC 2000 Wash
Changing the aperture ring
The MAC 2000 Wash comes factory fitted with a 50 mm (2 in) aperture ring (identified by 5 small holes), and 3
optional rings:
30 mm (1.2 in) - identified by 3 small holes
40 mm (1.6 in) - identified by 4 small holes
45 mm (1.8 in) - identified by 4 small holes and a half-crescent
Use of the smaller apertures will result in less light output and a narrower beam angle.
To change aperture ring:
1 Disconnect the fixture from power and allow it to cool.
2 Lock the head horizontally with the top cover up.
3 Remove the top cover of the fixture using a flathead screwdriver to unlock the four quarter-turn screws.
4 The additional aperture rings can be found secured to the chassis with a thumb screw just behind the front
lens (see the following illustration). Remove the thumb screw and select the appropriate aperture ring.
5 Remove the currently installed aperture ring, from just behind the zoom lens, by pushing and twisting it.
6 Install the replacement aperture ring, lock the others in place behind the front lens using the thumb screw,
and replace the fixture cover.