Basic service 19
Basic service
Before servicing the Magnum smoke machine, read and observe all the
precautions listed in “Safety information” on page 3. Any service not described in
this section must be carried out by a Martin service technician.
Cleaning
Excessive dust, smoke fluid, and dirt build-up will degrade performance and
cause overheating and damage to the machine that is not covered by the
product warranty. To maintain adequate cooling, dust must be cleaned from the
outer casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The smoke output nozzle remains hot for up to 10 hours after use.
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
Clean smoke fluid residues from the fog output of the machine using a
damp cloth.
Clean the outer casing with a damp cloth only.
Fuse replacement
The main fuse for the Magnum smoke machine is located on the electronics
board inside the unit.
DANGER! Disconnect the power supply before removing any covers. Live parts
inside!
To replace the fuse, disconnect the power cord from the supply, unscrew the
screws holding the top cover of the unit and remove the cover. The electronics
board is located at the back of the unit near the remote control sockets.
Remove the fuse holder cover and pull out the fuse. Remove the spent fuse and
replace with one of exactly the same size and rating. The fuse type is indicated
below. Contact Martin Service if the fuse blows repeatedly.
Magnum 1800
120V = 10AT
230V = 6.3AT
Magnum 1200
120V = 10AT
230V = 5AT
Page view 18