10 RUSH MH 4 Beam User Manual
Physical installation
Read ‘Safety information’ on page 4 before installing the
fixture.
The fixture is designed for indoor use only and must be used in
a dry location with adequate ventilation. Ensure that none of the
fixture’s ventilation slots are blocked and ensure that the
product is fastened to a secure structure or surface.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at any
angle. Ensure that the surface and all fasteners used can support at least 10
times the weight of all fixtures and equipment they will support.
Fasten the fixture securely. Do not stand it on a surface or leave it where it
can be moved or fall over. If you install the fixture in a location where it may
cause injury or damage if it falls, secure it as directed below with a securely
anchored safety cable that will hold the fixture if the primary fastening method
fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging
structure in any orientation. When installing the fixture
hanging vertically down, you can use an open-type clamp
such as a G-clamp. When installing in any other orientation,
you must use a half-coupler clamp (see illustration on right)
that completely encircles the truss chord.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight
of all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. The fixture is supplied with two omega-type brackets to which rigging
clamps can be attached. Bolt a rigging clamp securely to each bracket.
The bolts used must be M12, grade 8.8 steel minimum, and fastened with
self-locking nuts.
4. Fasten the omega brackets to the base of the fixture
using the brackets’ quarter-turn fasteners. Turn quarter-
turn fasteners a full 90° to lock them (see illustration on
right).