Page view 29
30 MAC 401 Dual
user manual
Onboard control menus
Single head module operation
When only one module is installed on the head and the HEAD menu is set to SNGL, the following control
menus are available:
Menu Item Options Notes (Default settings in bold print)
ADDR
1
– XXX
DMX address (default address = 1). The DMX address range is limited
so that the fixture will always have enough DMX channels in the 512
available.
DMX
PSET
RGBX
RGB mode with dynamic effects
HSX
HSV mode with dynamic effects
RGB
RGB mode without dynamic effects
HS
HSV mode without dynamic effects
PGRP
1
Individual control of 4 pixels (segments)
2H
Control of pixels in 2 groups of 2 pixels, horizontal split
2V
Control of pixels in 2 groups of 2 pixels, vertical split
All
All pixels controlled as one group
PINV
OFF
Disable pixel inversion
ON
Pixel inversion: pixels swapped left to right and top to bottom
PERS
PTST
PTSP
Pan and tilt speed normal / fast / slow
SWAP
Swap pan and tilt (pan commands move tilt and vice versa) - off / on
PINV
Pan inversion (reverse direction pan control) - off / on
TINV
Tilt inversion (reverse direction tilt control) - off / on
FANS
REG
Cooling fan speed thermostatically regulated
FULL
Max. cooling fan speed
SLNT
Silent mode. When Silent mode is selected the head fan will turn off.
The base fan will still run. Values allowed for RGB or HSV (no matter
what operating mode) will be limited to prevent the fixture from
producing too much heat. If the LEDs get too hot the fans will revert to
Regulated mode. When the LEDs are cool enough the fans shift back to
Silent mode. The color wheel channel will have lower intensity in Silent
mode.
DIM
LIN
Linear dimming curve
SQR
Square law dimming curve
ISQR
Inverse square law dimming curve
SCUR
S-curve dimming curve
DRES
OFF
Disable reset via DMX
ON
Enable reset via DMX
DISP
ON
Display is always on
2MN
Display switches off and goes into Sleep mode if the controls have
not been pressed for 2 minutes.
5MN
Display switches off and goes into Sleep mode if the controls have not
been pressed for 5 minutes
10MN
Display switches off and goes into Sleep mode if the controls have not
been pressed for 10 minutes
DINT 0-100
Display intensity. Default=100
ERRM
NORM
Display errors at 100% intensity (regardless of DINT setting) and
illuminate the service light.
SLNT
Silent error mode. The error message does not appear in the display,
but the service lamp is illuminated
CTC
WITH
Sending a value on a CTC channel adjusts the temperature of
whatever color is currently being displayed on segment or fixture
INDP
Sending a value on a CTC channel overrides any color being displayed.
Fixture or segment switches to white with variable color temperature
FACT
FACT LOAD
Return all settings (except calibrations) to factory defaults
NB: can take up to 2 minutes to complete!
CUS1,
CUS2,
CUS3
LOAD
Load custom configuration
SAVE
Save current custom configuration
Table 4: Control menu: single head module operation