  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
INFO
PTMP
CURR
Display current average pixel PCB temperature
MSR
Display highest pixel PCB temperature since last reset
MR
Display highest pixel PCB temperature since manufacture
AIRF
TOTL
Current elapsed time in hours since the air filter was cleaned or
changed. Display the counter and press the up button for five seconds
to reset it.This counter must be reset manually when the air filter is
cleaned.
STTM
Set duration of time alert to be issued after 100-9999 hours have
passed on the
TOTL counter, to remind you to clean it, particularly the
air filter. The alert appears as long as the value of the
TOTL counter
is higher than the threshold set here.
SNUM
RDM
Display fixture’s RDM ID
SNUM
Display fixture’s serial number
MAN
RST
Reset fixture. Press [Enter] to confirm
ALL 0 255
All LEDs, intensity 0 - 100%
RED 0 255
Red LEDs, intensity 0 - 100%
GRN1 0 255
Green 1, intensity 0 - 100%
GRN2 0 255
Green 2, intensity 0 - 100%
BLUE 0 255
Blue, intensity 0 - 100%
ZOOM 0 255
Zoom full wide zoom full narrow (Hypermode)
TILT 0 255
Full tilt full opposite tilt
PAN 0 255
Pan full left pan full right
TEST
TALL
Test LEDs, zoom and pan/tilt movement
T-FX
Test LEDs and zoom only
TP-T
Test pan/tilt movement only
TDIS
Light all segments in onboard display panel for 5 secs.
PERS
PTST
PTSP
Pan and tilt speed normal / fast / slow
SWAP
Swap pan and tilt (pan commands move tilt and vice versa) - off / on
PINV
Pan inversion (reverse direction pan control) - off / on
TINV
Tilt inversion (reverse direction tilt control) - off / on
FANS
REG
Cooling fan speed thermostatically regulated
FULL
Max. cooling fan speed
SLNT
Silent mode. When Silent mode is selected the head fan will turn off.
The base fan will still run. Values allowed for RGB or HSV (no matter
what operating mode) will be limited to prevent the fixture from
producing too much heat. If the LEDs get too hot the fans will revert to
Regulated mode. When the LEDs are cool enough the fans shift back to
Silent mode. The color wheel channel will have lower intensity in Silent
mode.
DIM
LIN
Linear dimming curve
SQR
Square law dimming curve
ISQR
Inverse square law dimming curve
SCUR
S-curve dimming curve
DRES
OFF
Disable reset via DMX
ON
Enable reset via DMX
DISP
ON
Display is always on
2MN
Display switches off and goes into Sleep mode if the controls have
not been pressed for 2 minutes.
5MN
Display switches off and goes into Sleep mode if the controls have not
been pressed for 5 minutes
10MN
Display switches off and goes into Sleep mode if the controls have not
been pressed for 10 minutes
DINT 0-100
Display intensity. Default=100
ERRM
NORM
Display errors at 100% intensity (regardless of  setting) and
illuminate the service light.
SLNT
Silent error mode. The error message does not appear in the display,
but the service lamp is illuminated
CTC
WITH
Sending a value on a CTC channel adjusts the temperature of
whatever color is currently being displayed on segment or fixture
INDP
Sending a value on a CTC channel overrides any color being displayed.
Fixture or segment switches to white with variable color temperature
Menu Item Options Notes (Default settings in bold print)
Table 6: Control menu: dual head module operation, REAR menu